Bosch, Siemens and Hansa error codes and malfunctions

Description E1, E2, E3, E4 error codes and Siemens, Hansa and Bosch refrigerators repair. Bosch and Siemens household manufacturers are recognized on the world market one of the most reliable and faults of the Bosch refrigerator, like Siemens refrigerators, are very rare. However, nothing forever and the technique of these brands, like any other, also fails. Most of the refrigerators are equipped with a display on which the error code will be displayed in case of breakdown of the refrigerator. Control boards display Bosch refrigerators and Siemens refrigerators and look like two drops of water. They use the general standard for withdrawing diagnostic messages. Also, this standard for displaying errors is used in Hansa refrigerators. Hansa is one of the leading household appliances in the world market.

With repair of refrigerators Bosch, Siemens and Hansa, it is important to know the meaning of error codes:

  • Е1 - The temperature sensor of the refrigerator failed. Functionally, it is designed to support the necessary temperature and its failure precedes its mandatory replacement. If you have certain skills, you can try to replace the sensor yourself.
  • Е2 - The capacitor thermal sensor is faulty. It is in an inaccessible place and replace it on your own. Call a specialist.
  • Е3 - The temperature sensor of the freezer is faulty. The service life of this sensor is limited by a certain time and its replacement is early or precisely necessary in any refrigerator.
  • Е4 - The temperature sensor of the freezer capacitor failed. Replacement is required. As in the case of a refrigerator capacitor, a replacement capacitor, its replacement is performed only by a specialist.

As you can see all the malfunctions of the refrigerators Bosch, Siemens and Hansa refrigerators are associated with the failure of temperature sensors. Along with the code that appears, errors also appear the following malfunctions:

  • The compressor works continuously. In this case, the temperature in the refrigerator and freezers is not gained.
  • The compressor engine does not turn on. At the same time, light is on in the refrigerators chamber
  • The compressor turns on for a short time
  • The refrigerator begins to work noisily
  • The compressor does not turn off, even if the temperature in the chambers already corresponds to the required
Acer | Aeg | Aiwa | Akai | Bauknecht | Canon | Casio | Clarion | Compaq | Daewoo | Dell | Electrolux | Grundig | HP | Haier | Hitachi | ITT | JVC | Kenwood | LG | Lenovo | Loewe | Midea | Mitsubishi | Neckermann | Nokia | Nordmende | Others | Panasonic | Philips | Pioneer | Privileg | Quelle | RCA | Ricoh | Royal | Saba | Samsung | Sanyo | Sharp | Siemens | Sony | Technics | Telefunken | Thomson | Toshiba | Viewsonic | Whirlpool | Yamaha | Zanussi | Show all brands